Title: Análisis exérgico y entropía de los ciclos de Brayton del PCRC y RCMCI utilizando mezclas de s-CO2: Estudio de caso: Aplicaciones marinas
metadata.dc.title.en: Exergetic and Entropy Analysis of the PCRC and RCMCI Brayton Cycles Using s-CO2 Mixtures: Case Study: Marine Applications
Authors: Tafur Escanta, Paul Michael
Valencia Chapi, Robert
Muñoz Antón, Javier
metadata.dc.contributor.orcid: https://orcid.org/0000-0002-0760-6350
https://orcid.org/0000-0003-1977-2118
https://orcid.org/0000-0002-1980-0863
metadata.dc.type: Article
Keywords: DIÓXIDO DE CARBONO;FLUIDOS SUPERCRÍTICOS;TERMODINÁMICA
metadata.dc.subject.en: CARBON DIOXIDE;SUPERCRITICAL FLUIDS;THERMODYNAMICS
Issue Date: 18-Mar-2026
metadata.dc.date.created: 27-Apr-2023
Publisher: Editorial de la Universidad de Duisburg-Essen
Abstract: El ciclo de Brayton que utiliza dióxido de carbono supercrítico (s-CO2) como fluido de trabajo es una tecnología de alta eficiencia que ha sido un estudio para su mejora. El rendimiento de los ciclos lo explica mediante un análisis termodinámico que tiene en cuenta dos aspectos: por un lado, una tendencia general en su comportamiento y, por otro, el efecto de las irreversibilidades, especialmente las irreversibilidades que ocurren en el regenerador. Este estudio se centra en el impacto de mezclas binarias basadas en CO2 puro en la eficiencia térmica de las configuraciones: ciclos de Recompresión con Intercooling del Compresor Principal (RCMCI) y Enfriamiento Parcial con Recompresión (PCRC) en el punto de diseño, considerando las irreversibilidades causadas por cada componente del ciclo. En el ciclo PCRC se consiguen recuperadores de calor de tamaño pequeño y recuperadores de baja temperatura y alta temperatura. La eficiencia en el ciclo RCMCI es mejor debido al bajo trabajo de recompresor. La metodología utilizada en el cálculo del rendimiento de la planta consiste en establecer valores de conductancia total de los recuperadores de calor entre 5 y 20 MW/K. Basándose en el análisis exérgico y de entropía de los ciclos estudiados, se realiza una comparación entre mezclas puras de dióxido de carbono supercrítico y s-CO2 (CO2/CH4, C3H8 y CO2/H2S). Los resultados obtenidos han revelado que las mezclas aumentan la eficiencia térmica en comparación con el fluido estándar en los ciclos estudiados. En configuraciones PCRC, la mezcla que obtiene la mayor eficiencia es la que contiene metano, mientras que en las configuraciones RCMCI es la que contiene sulfuro de hidrógeno. Mientras tanto, en el ciclo RCC, la mezcla con propano es la que tiene mayor eficiencia.
metadata.dc.description.abstract-en: Brayton cycle using supercritical carbon dioxide (s-CO2) as a working fluid is a high-efficiency trend technology that has been an understudy for improvement. The performance of the cycles explains with a thermodynamic analysis that accounts for two aspects: on one side a general trend in their behavior and on the other the effect of the irreversibilities, especially the irreversibilities taking place in the regenerator. This study focuses on the impact of binary mixtures based on pure CO2 on the thermal efficiency of the configurations: Recompression with Main Compressor Intercooling (RCMCI) and Partial Cooling with Recompression (PCRC) cycles at the design point, considering the irreversibilities caused by each component of the cycle. In the PCRC cycle, small-size heat recuperators and low-temperature high-heat recuperators are achieved. The efficiency in the RCMCI cycle is better due to the low recompressor work. The methodology used in the calculation of the plant performance is to establish heat recuperator total conductance values of between 5 and 20 MW/K. Based on the exergetic and entropy analysis of the cycles studied, a comparison between pure supercritical carbon dioxide and s-CO2 mixtures (CO2/CH4, C3H8, and CO2/H2S) is carried out. Acquired results have revealed that the blends increase thermal efficiency compared to the standard fluid in the cycles studied. In PCRC configurations, the mixture that obtains the highest efficiency is the one that contains Methane, while in RCMCI configurations it is the one that contains Hydrogen Sulfide. Meanwhile, in the RCC cycle, the mixture with Propane is the one with the highest efficiency.
URI: https://repositorio.utn.edu.ec/handle/123456789/19286
metadata.dc.identifier.doi: https://duepublico2.uni-due.de/receive/duepublico_mods_00077263
metadata.dc.coverage: Ibarra. Ecuador
metadata.dc.description.degree: N/A
Appears in Collections:Artículos

Files in This Item:
There are no files associated with this item.


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons