https://repositorio.utn.edu.ec/handle/123456789/19078| Title: | Mezclas de CO₂ supercrítico para ciclos de potencia Brayton en configuraciones complejas con energía solar de concentración |
| metadata.dc.title.en: | Supercritical CO2 mixtures for Brayton power cycles complex configurations with concentrating solar power |
| Authors: | Valencia Chapi, Robert Tafur Escanta, Paul Coco Enríquez, Luis Muñoz Antón, Javier |
| metadata.dc.contributor.orcid: | https://orcid.org/0000-0003-1977-2118 https://orcid.org/0000-0002-0760-6350 https://orcid.org/0000-0002-3655-2654 https://orcid.org/0000-0002-1980-0863 |
| metadata.dc.type: | Article |
| Keywords: | RECALENTAMIENTO;FRACCIÓN;IMPACTO |
| metadata.dc.subject.en: | REHEATING;FRACTION;IMPACT |
| Issue Date: | 4-Mar-2026 |
| metadata.dc.date.created: | 12-May-2022 |
| Publisher: | AIP Conference Proceedings |
| Abstract: | Se presenta una evaluación del impacto del uso de mezclas de dióxido de carbono supercrítico (s-CO₂/C₂H₆, s-CO₂/CH₄, s-CO₂/Kr y s-CO₂/SF₆) como fluido de trabajo en ciclos de potencia Brayton con s-CO₂. Las configuraciones complejas consideradas incluyen: recompresión con dos recalentamientos (RCC–2RH), recompresión con tres recalentamientos (RCC–3RH), recompresión con intercooling en el compresor principal y dos recalentamientos (RCMCI–2RH), y recompresión con intercooling en el compresor principal y tres recalentamientos (RCMCI–3RH). Estas configuraciones se acoplaron a un sistema solar de enfoque lineal que utiliza Solar Salt (60% NaNO₃ / 40% KNO₃) como fluido de transferencia de calor (HTF). Los parámetros de diseño evaluaron el desempeño de la planta solar en el punto de diseño, el área de apertura del campo solar y las variaciones de costos en función de la conductancia total de la planta (UA_total). La metodología empleada para calcular el desempeño estableció valores de conductancia total del recuperador de calor (UA_total) entre 5 y 25 MW/K. La principal conclusión indica que la eficiencia del ciclo mejora considerablemente en comparación con la obtenida utilizando s-CO₂ puro. La mezcla s-CO₂/Kr con una fracción molar de 30/70 incrementa la eficiencia del ciclo entre 7–11% respecto al s-CO₂ puro, dependiendo del UA_total. La mezcla s-CO₂/CH₄ con una fracción molar de 45/55 incrementa la eficiencia entre 3–7%, mientras que las mezclas s-CO₂/C₂H₆ y s-CO₂/SF₆ solo presentan aumentos del 1–2%. En cuanto a los costos unitarios del campo solar, la mezcla s-CO₂/Kr presenta el menor costo, entre 29 y 34 millones de USD, dependiendo del área de apertura del campo solar y del UA_total para las configuraciones RCC-2RH y RCMCI-2RH. Finalmente, los resultados demuestran que las variaciones en las propiedades del fluido de trabajo desempeñan un papel significativo debido al impacto positivo en el aumento de la eficiencia térmica del ciclo Brayton con s-CO₂ cuando se utilizan las configuraciones RCC y RCMCI. |
| metadata.dc.description.abstract-en: | An evaluation of the impact of using supercritical carbon dioxide mixtures (s-CO2/C2H6, s-CO2/CH4, s-CO2/Kr, and s-CO2/SF6) as a working fluid is made here for Brayton s-CO2 power cycles. The considered complex configurations include recompression with two reheating (RCC–2RH), recompression with three reheating (RCC–3RH), recompression with main compressor intercooling and two reheating (RCMCI–2RH), and recompression with main compressor intercooling and three reheating (RCMCI–3RH), which were coupled to a linear-focus solar system with Solar Salt (60% NaNO3/40% KNO3) as the heat transfer fluid (HTF). The design parameters evaluated the solar plant performance at the design point, the aperture area of the solar field, and variations in costs regarding the plant’s total conductance (UAtotal). The methodology used to calculate the performance established the total conductance values of the heat recuperator (UAtotal) to between 5 and 25 MW/K. The main conclusion is that the cycle efficiency has a considerable improvement compared with that obtained using pure s-CO2. The s-CO2/Kr mixture with a molar fraction ratio of 30/70 increases the cycle efficiency between 7–11% relative to pure s-CO2 and as a function of the UAtotal. The s-CO2/CH4 mixture with a molar fraction of 45/55 increases between 3–7%, and the s-CO2/C2H6 and s-CO2/SF6 mixtures only increase between 1– 2%. For the solar field unitary costs, the s-CO2/Kr mixture has the lowest cost at $29–34 million USD, which depends on the solar field aperture area and the UAtotal for the RCC-2RH and RCMCI-2RH configurations. Finally, the results demonstrate that variations in the working fluid properties play a significant role due to the positive impact on the increased thermal efficiency of the s-CO2 Brayton cycle when using the RCC and RCMCI configurations. |
| URI: | https://repositorio.utn.edu.ec/handle/123456789/19078 |
| metadata.dc.identifier.doi: | https://doi.org/10.1063/5.0086032 |
| ISSN: | 0094-243X |
| metadata.dc.coverage: | Ibarra-Ecuador |
| metadata.dc.description.degree: | N/A |
| Appears in Collections: | Artículos |
Files in This Item:
There are no files associated with this item.
This item is protected by original copyright |
This item is licensed under a Creative Commons License